carda-engineering    used machines

CHP used Köhler / Ziegler / E-1349

This used Köhler / Ziegler type SY 53 GSM CHP plant (Ref. E-1349) is a compact combined heat and power (CHP) unit, primarily designed for operation with sewage gas or biogas in municipal and industrial facilities.

Used Köhler / Ziegler SY 53 GSM CHP plant technical data

Name:
CHP used
Manufacturer:
Köhler / Ziegler
Type:
SY 53 GSM
Year built:
2005
CardaID:
E-1349

Generator:
Leroy Somer
Generator Type:
LSA44.2S7/4
Generator kW:
132 kVA
Turbo:
No
Driving force:
MAN E0836 E302, 6 Zylinder, 56kW
Fuel type:
Sewage gas
Electrical power:
53 kW
Thermal power:
87 kW
Dimensions:
L 3.600 x W 950 x H 1.750 mm

Empty weight:
2.200 kg
Technical doc.:
Yes
Message:
The engine was replaced in 2013
Condition:
Second hand
Price:
On demand
CHP used Köhler / Ziegler | E-1349_1 Startbild
CHP used Köhler / Ziegler | E-1349_1
CHP used Köhler / Ziegler | E-1349_2
CHP used Köhler / Ziegler | E-1349_3
CHP used Köhler / Ziegler | E-1349_4
Type label CHP used v E-1349_5

Performance features of the used CHP plant

  • Electrical output: 53 kW (for grid-parallel operation, non-overloadable)
  • Thermal output: 87 kW (heating energy designed for 90/70 °C)
  • Energy input / fuel power: 158 kW
  • Tolerance: ± 5 % for thermal output and energy input
  • Three-phase current: 400 V, 50 Hz +/- 5%
  • Fuel: Sewage gas
  • High overall efficiency: The simultaneous generation of electricity and heat achieves an overall efficiency of over 88 %
  • Robust naturally aspirated engine: The installed MAN E0836 E302 gas engine dispenses with turbocharging, making it extremely low-maintenance and durable
  • Tolerance to gas quality: The system is insensitive to slight fluctuations in the methane content of the gas used
  • Synchronous generator module: Enables excellent grid stability and reactive power control in parallel operation thanks to the Leroy Somer generator
  • Compact frame design: All core components (engine, generator, heat exchanger) are pre-assembled on a torsion-resistant base frame, minimizing on-site installation effort
  • Integrated control cabinet system: Fully automatic monitoring of grid parameters, oil pressure, cooling water temperature, and exhaust gas values

Main fields of application for used combined heat and power plants

  • Municipal wastewater treatment plants: Utilization of the sewage gas produced on-site for self-generation of electricity and for heating the digesters
  • Agricultural biogas plants: Power generation from biogas in smaller plants or as a satellite CHP unit for decentralized heat supply
  • Industrial facilities: Utilization of process gases or natural gas in operations with a constantly high and simultaneous demand for electricity and heat (e.g., food or textile industry)
  • District heating networks & local energy concepts: Feeding the thermal output of 87 kW into local heating networks to supply public buildings or residential areas
  • Hospitals and nursing homes: Provision of base load electricity and continuous hot water or heating energy around the clock

Management, transport & worldwide delivery

The used Köhler / Ziegler type SY 53 GSM CHP plant (Ref. E-1349) can be inspected by prior appointment. Upon request, we will gladly organize loading and transport as well as, if required, export and customs clearance.

REQUEST A NON-BINDING QUOTE NOW or VIEW MORE USED CHPs AND POWER GENERATORS FOR SALE